Volume 34 Issue 8
Jul.  2022
Turn off MathJax
Article Contents
Ma Na, Li Bo, Dong Lan, et al. Analysis of calibration schemes for CSNS quadrupole[J]. High Power Laser and Particle Beams, 2022, 34: 084002. doi: 10.11884/HPLPB202234.210512
Citation: Ma Na, Li Bo, Dong Lan, et al. Analysis of calibration schemes for CSNS quadrupole[J]. High Power Laser and Particle Beams, 2022, 34: 084002. doi: 10.11884/HPLPB202234.210512

Analysis of calibration schemes for CSNS quadrupole

doi: 10.11884/HPLPB202234.210512
  • Received Date: 2021-08-24
  • Accepted Date: 2022-04-14
  • Rev Recd Date: 2022-04-01
  • Available Online: 2022-04-21
  • Publish Date: 2022-07-20
  • This paper focuses on the calibration of the quadrupole of CSNS about determination of the center of the devices, analyzes the standard deviation values of magnetic center and rotation center obtained by the magnetic measuring platform, and the one of rotation center and mechanical center after the calibration of each magnet twice. The results show that the standard deviation of magnetic center and rotation center of the quadrupole obtained by the magnetic measuring platform is 0.1 mm, the repeatability accuracy after the calibration of the rotation center and the mechanical center of the CSNS quadrupole twice is within 0.03 mm, and the standard value of the deviation between the rotation and the mechanical center is 0.1 mm. Therefore, if the magnet center calibration cannot be carried out for similar devices of the same accuracy, the calibration based on rotation center instead of mechanical center, with deviation correction of rotation center and magnetic center, can meet the accuracy requirements of the current equipment alignment. This study provides important reference and guidance for the calibration of similar devices in the future.
  • loading
  • [1]
    王铜, 梁静, 董岚, 等. 粒子加速器设备标定中基准面引出研究[J]. 原子能科学技术, 2016, 50(8):1524-1527. (Wang Tong, Liang Jing, Dong Lan, et al. Research on layout of datum plane in equipment fiducialisation of particle accelerator[J]. Atomic Energy Science and Technology, 2016, 50(8): 1524-1527 doi: 10.7538/yzk.2016.50.08.1524

    Wang Tong, Liang Jing, Dong Lan, et al. Research on layout of datum plane in equipment fiducialisation of particle accelerator[J]. Atomic Energy Science and Technology, 2016, 50(8): 1524-1527 doi: 10.7538/yzk.2016.50.08.1524
    [2]
    梁静, 罗明成, 王铜, 等. 粒子加速器中高精度丝线绝对位置测量技术研究[J]. 测绘通报, 2019(9):44-50. (Liang Jing, Luo Mingcheng, Wang Tong, et al. Research on the wire absolute position measurement technology of high accuracy in particle accelerator[J]. Bulletin of Surveying and Mapping, 2019(9): 44-50

    Liang Jing, Luo Mingcheng, Wang Tong, et al. Research on the wire absolute position measurement technology of high accuracy in particle accelerator[J]. Bulletin of Surveying and Mapping, 2019(9): 44-50
    [3]
    梁静, 董岚, 王铜, 等. 激光跟踪仪在CSNS高频腔预准直中的应用[J]. 地理空间信息, 2017, 15(3):12-13,19. (Liang Jing, Dong Lan, Wang Tong, et al. Application of laser tracker in the pre-alignment of RF cavity for CSNS[J]. Geospatial Information, 2017, 15(3): 12-13,19

    Liang Jing, Dong Lan, Wang Tong, et al. Application of laser tracker in the pre-alignment of RF cavity for CSNS[J]. Geospatial Information, 2017, 15(3): 12-13, 19
    [4]
    吴蕾, 王小龙, 李春华, 等. 高能同步辐射光源验证装置振动线准直系统结构设计[J]. 强激光与粒子束, 2015, 27:095102. (Wu Lei, Wang Xiaolong, Li Chunhua, et al. Design of vibrating wire alignment system for HEPS-TF[J]. High Power Laser and Particle Beams, 2015, 27: 095102 doi: 10.11884/HPLPB201527.095102

    Wu Lei, Wang Xiaolong, Li Chunhua, et al. Design of vibrating wire alignment system for HEPS-TF[J]. High Power Laser and Particle Beams, 2015, 27: 095102 doi: 10.11884/HPLPB201527.095102
    [5]
    王小龙, 吴蕾, 陈素颖, 等. 振动线数据采集和数据处理方案设计与验证[J]. 强激光与粒子束, 2016, 28:125106. (Wang Xiaolong, Wu Lei, Chen Suying, et al. Design and experiment of vibrating wire data acquisition and processing system[J]. High Power Laser and Particle Beams, 2016, 28: 125106 doi: 10.11884/HPLPB201628.160144

    Wang Xiaolong, Wu Lei, Chen Suying, et al. Design and experiment of vibrating wire data acquisition and processing system[J]. High Power Laser and Particle Beams, 2016, 28: 125106. doi: 10.11884/HPLPB201628.160144
    [6]
    吴蕾, 王小龙, 李春华, 等. 振动线准直技术的原理和研究概述[J]. 强激光与粒子束, 2013, 25(10):2479-2486. (Wu Lei, Wang Xiaolong, Li Chunhua, et al. Theory and research overview of vibrating wire technique[J]. High Power Laser and Particle Beams, 2013, 25(10): 2479-2486 doi: 10.3788/HPLPB20132510.2479

    Wu Lei, Wang Xiaolong, Li Chunhua, et al. Theory and research overview of vibrating wire technique[J]. High Power Laser and Particle Beams, 2013, 25(10): 2479-2486 doi: 10.3788/HPLPB20132510.2479
    [7]
    Penicka J M, Collins J, Doose C, et al. Alignment strategy for APS upgrade[C]//Proceedings of the 14th International Workshop on Accelerator Alignment. Grenoble: ESRF, 2016.
    [8]
    马娜, 董岚, 梁静, 等. 中国散裂中子源隧道控制网测量方法及精度探讨[J]. 核科学与工程, 2018, 38(3):411-416. (Ma Na, Dong Lan, Liang Jing, et al. Measurement of the tunnel control network of CSNS and accuracy research[J]. Nuclear Science and Engineering, 2018, 38(3): 411-416 doi: 10.3969/j.issn.0258-0918.2018.03.011

    Ma Na, Dong Lan, Liang Jing, et al. Measurement of the tunnel control network of CSNS and accuracy research[J]. Nuclear Science and Engineering, 2018, 38(3): 411-416 doi: 10.3969/j.issn.0258-0918.2018.03.011
    [9]
    陈文军, 马力祯, 蔡国柱, 等. 武威重离子治癌装置高能束线的准直安装[J]. 强激光与粒子束, 2015, 27:085102. (Chen Wenjun, Ma Lizhen, Cai Guozhu, et al. Alignment of high energy line for Wuwei heavy ion medical machine[J]. High Power Laser and Particle Beams, 2015, 27: 085102 doi: 10.11884/HPLPB201527.085102

    Chen Wenjun, Ma Lizhen, Cai Guozhu, et al. Alignment of high energy line for Wuwei heavy ion medical machine[J]. High Power Laser and Particle Beams, 2015, 27: 085102 doi: 10.11884/HPLPB201527.085102
    [10]
    周建新, 康文, 李帅, 等. 中国散裂中子源旋转线圈测量系统研制[J]. 强激光与粒子束, 2018, 30:105101. (Zhou Jianxin, Kang Wen, Li Shuai, et al. Development of rotating coil measurement system for China Spallation Neutron Source[J]. High Power Laser and Particle Beams, 2018, 30: 105101 doi: 10.11884/HPLPB201830.180186

    Zhou Jianxin, Kang Wen, Li Shuai, et al. Development of rotating coil measurement system for China Spallation Neutron Source[J]. High Power Laser and Particle Beams, 2018, 30: 105101 doi: 10.11884/HPLPB201830.180186
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(9)  / Tables(3)

    Article views (481) PDF downloads(37) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return