[1] Powers T. Theory and practice of cavity RF test system[C]//Proceedings of the 12th International Workshop on RF Superconductivity. 2005: 40-70.
[2] Delayen J R. Phase and amplitude stabilization of superconducting resonators[D]. California: California Institute of Technology, 1978: 1-16.
[3] Allison T, Delayen J R, Hovater C, et al. A digital self excited loop for accelerating cavity field control[C]//Proceedings of PAC07. 2007: 2481-2483.
[4] Goryashko V A, Bhattacharyya A K, Li Han, et al. A method for high-precision characterization of the Q-slope of superconducting RF cavities[J]. IEEE Transactions on Microwave Theory and Techniques, 2016, 64(11): 3764-3771. doi: 10.1109/TMTT.2016.2605671
[5] Nicander H. Electro-acoustic stability of a superconducting spoke cavity[D]. Sweden: Uppsala University, 2015: 31-37.
[6] 张娟, 戴建枰, 黄泓, 等. 基于Labview 的超导腔测试数据采集系统[J]. 核电子学与探测技术, 2013, 33(9):1098-1103. (Zhang Juan, Dai Jianping, Huang Hong, et al. Data acquisition system of superconducting cavity test based on Labview[J]. Nuclear Electronics & Detection Technology, 2013, 33(9): 1098-1103 doi: 10.3969/j.issn.0258-0934.2013.09.014
[7] 常玮. 低beta超导腔体的测试研究[D]. 兰州: 中国科学院近代物理研究所, 2014: 62-68.

Chang Wei. Research on low beta superconducting cavity testing[D]. Lanzhou: Institute of Modern Physics, Chinese Academy of Sciences, 2014: 62-68
[8] 邱丰. 1.3 GHz 9-cell腔数字化低电平系统的研究[D]. 北京: 中国科学院高能物理研究所, 2012: 76-77.

Qiu Feng. Study on the digital low level RF control system of 1.3 GHz nine-cell cavity[D]. Beijing: Institute of High Energy Physics, Chinese Academy of Sciences, 2012: 76-77
[9] 张志刚. 同步辐射光源增强其高频数字化低电平系统研制[D]. 上海: 中国科学院 上海应用物理研究所, 2015: 68-72.

Zhang Zhigang. Development of digital low level RF system for booster at Synchrotron Radiation Light Source[D]. Shanghai: Shanghai Institute of Applied Physics, Chinese Academy of Sciences, 2015: 68-72
[10] Holzbauer J P, Pischalnikov Y, Sergatskov D A, et al. Systematic uncertainties in RF-based measurement of superconducting cavity quality factors[J]. Nuclear Instruments and Methods in Physics Research A, 2016, 830: 22-29. doi: 10.1016/j.nima.2016.05.025
[11] Holzbauer J P, Contreras C, Pischalnikov Y, et al. Improved RF measurements of SRF cavity quality factors[J]. Nuclear Instruments and Methods in Physics Research A, 2019, 913: 7-14. doi: 10.1016/j.nima.2018.09.155
[12] 刘亚萍. BEPCII 500 MHz 铌腔的研制[D]. 北京: 中国科学院高能物理研究所, 2011: 94-95.

Liu Yaping. Study of BEPCII 500 MHz niobium cavity[D]. Beijing: Institute of High Energy Physics, Chinese Academy of Sciences, 2011: 94-95