[1] Peplow M. The next big hit in molecule Hollywood[J]. Nature News, 2017, 544(7651): 408. doi: 10.1038/544408a
[2] Johnson C B. Photoelectronic streak-tube technology review[C]//Proc of SPIE. 1977, 94: 13-18
[3] Trebino R, Daniel J K. Using phase retrieval to measure the intensity and phase of ultrashort pulses: frequency resolved optical gating[J]. J of Opt Soc Am A, 1993, 10(5): 1101-1111. doi: 10.1364/JOSAA.10.001101
[4] Iaconis C, Walmsley I A. Spectral phase interferometry for direct electric-field reconstruction of ultrashort optical pulses[J]. Opt Lett, 1998, 23(10): 792-794. doi: 10.1364/OL.23.000792
[5] Sabrina R Nagela, Hilsabeck T J, Ayers M J, et al. 2D magnetic field warp reversal in images taken with DIXI (dilation X-ray imager)[C]//Proc of SPIE. 2016: 88500I.
[6] Sun RenPing, Lai XuanYang, Liu Xiaojun, et al. Tomographic extraction of the internuclear separation based on two-center interference with aligned diatomic molecules[J]. Phys Rev Lett, 2019, 122: 193202.
[7] Itatani J, Quéré F, Corkum P B, et al. Attosecond streak camera[J]. Phys Rev Lett, 2002, 88: 173903. doi: 10.1103/PhysRevLett.88.173903
[8] Zhao Kun, Zhang Qi, Chang Zenghu, et al. Multiphoton processes and attosecond physics[M]//Route to One Atomic Unit of Time: Development of a Broadband Attosecond Streak Camera.2012.
[9] Yurtsever A , Zewail A H. 4D nanoscale diffraction observed by convergent-beam ultrafast electron microscopy[J]. Science, 209, 326: 708-712.
[10] Nakagawa K, Iwasaki A, Sakuma I, et al. Sequentially timed all-optical mapping photography (STAMP)[J]. Nature Photon, 2014, 8: 695-700. doi: 10.1038/nphoton.2014.163
[11] Yu Lu, Chen Feng, Wang Lidai. Compressed ultrafast spectral-temporal photography[J]. Phys Rev Lett, 2019, 122: 193904. doi: 10.1103/PhysRevLett.122.193904
[12] Conrtney-Pratt J S. A new method for the photographic study of fast transient phenomena[J]. Research Supply, 1949, 2(6): 287-295.
[13] Bradley D J, Liddy B, Sleat W E. Direct linear measurement of ultrashort light pulses with a picosecond streak camera[J]. Optics Communication, 1971, 8(2): 391-395.
[14] 顾礼. X射线飞秒条纹变像管设计与性能提高研究[D]. 深圳: 深圳大学, 2015, 10-13.

Gu Li. Research on X-ray femtosecond streak tube design and performance improvement[D]. Shenzhen: Shenzhen University, 2015: 10-13.
[15] Howorth J, Milnes J, Fisher Y, et al. The development of a streak tube with improved time and spatial resolution [C]//Proc of SPIE. 2017: 103280Q.
[16] Sibbett W, Niu H, Baggs M R. Femtosecond streak image tube[C]//Proc of SPIE. 1983, 348: 271-275.
[17] Katsuyuki K, Motohiro S, Yoshinori I, et al. Femtosecond streak tube[C]//Proc of SPIE. 1993, 1982: 180-185.
[18] Chang Zenghu, Rundquist A, Kapteyn H, et al. Demonstration of a 0. 54-ps X-ray streak camera[C]//Proc of SPIE. 1997, 2869: 971-976.
[19] Feng J, Shin H J, Young A T, et al. An X-ray streak camera with high spatio-temporal resolution[J]. Appl Phy Lett, 2007, 91: 134102. doi: 10.1063/1.2793191
[20] 牛憨笨. 变像管诊断技术[J]. 光子学报, 1988, 18(1):196-205. (Niu Hanben. Technique of image tube diagnostics[J]. Acta Photonics, 1988, 18(1): 196-205
[21] 薛鸣球, 黄玉金, 赵葆常, 等. 光学系统时间畸变和色时间滞后的研究[J]. 光子学报, 1995, 24(6):481-483. (Xue Mingqiu, Huang Yujin, Zhao Baochang, et al. Research on the aberration and spectral lag off of optical system[J]. Acta Photonics, 1995, 24(6): 481-483
[22] Shakya M M, Chang Zenghu. An accumulative X-ray streak camera with 280-fs resolution[C]//Proc of SPIE. 2004, 5534: 125-131.
[23] Danilenko K N, Zyuzin L N, Slavnov Yu K, et al. High-speed image converter instrument engineering of VNIIOFI is 40 years old[C]//Proc of SPIE. 2007: 627908.
[24] Zavoisky E K, Fanchenko S D. Image converter high-speed photography with 10-9~10-14sec time resolution[J]. Appl Opt, 1965, 4(9): 1155-1167. doi: 10.1364/AO.4.001155
[25] Friedman W, Jackel S. Dynamic range and spatial resolution of picoseconds streak cameras[C] // Proc of SPIE. 1976, 97: 544-547.
[26] Ageeva N V, Andreev S V, Schelev M, et al. Sub-100 fs streak tube: computer-aided design, manufacturing, and testing[C]//Proc of SPIE. 2009: 71261B.
[27] Kinoshita K, Suyama M, Ito M, et al, Femtosecond streak tube[C]//Proc of SPIE. 1990, 1358: 490-491.
[28] Lebedev V B, Feldman G G, Veinbein P, et al. Development and testing of subpicosecond streak camera for soft X-ray measurements[C]//Proc of SPIE. 1999, 3516: 74-84.
[29] Kinoshita K, Ishihara Y, Abe S, et al. Development of a single-shot streak tube with 100 fs time resolution[C]//The 31st International Congress on High-speed Imaging and Photonics. 2016: 305-310.
[30] https: //www. hamamatsu. com/eu/en/product/photometry-systems/streak-camera/index. html
[31] Girard A, Loty C, Allamargot J L, et al, P 700 : A new high speed streak tube with lamellar electron optics[C] // Proc of SPIE. 1984, 491: 58-62.
[32] Alain Mens, Dominique Gontier, Huilizen J C, et al. High-spatiotemporal-resolution X-ray streak cameras with bilamellar tubes: experimental confirmation of the performance[C]//Proc of SPIE. 1993, 1801: 502-513.
[33] Mens A, Dalmasso J M, Sauneuf R, et al. C 850X picosecond high-resolution streak camera[C]// Proc of SPIE. 1993, 1358: 315-328.
[34] Gallant P, Forget P, Kieffer J C, et al. Characterization of a subpicosecond X-ray streak camera for ultrashort laser-produced plasmas experiments[J]. Rev Sci Instrum, 2000, 71(10): 3627-3633. doi: 10.1063/1.1310347
[35] De Mascureau J, Mens A, Mexmain J M, et al, C 850 X-ray streak camera with optimized spatio-temporal resolution[C]//Proc of SPIE. 1988, 981: 86-92.
[36] https://www.photonis.com/products/streak-tubes/index.html
[37] Rebuffie J C, Mens A, New streak tubes of the P500 series: features and experimental results[C]// Proc of SPIE. 1990, 1358: 511-523.
[38] Niu H, Sibbett W. Theoretical analysis of space charge effects in photochron streak camera[J]. Rev Sci Instrum, 1981, 52(12): 1830-1836. doi: 10.1063/1.1136540
[39] Niu H, Zhang H, Wang X H, et al. A new picosecond synchroscan streak image tube [C]//Proc of SPIE. 1988, 1032: 468-471
[40] Guo Baoping, Niu Hanben. Synchroscan streak camera with fixed frequency for diagnosing light pulses with arbitrary repetition rates[C]//Proc of SPIE. 1997, 2869: 149-153.
[41] Niu Hanben, Zhang Hai, Yang Qinlao, et al. Experimental study of femtosecond streak image tube[C]//Proc of SPIE. 1992, 1801: 1035-1041.
[42] Qu Junle, Niu Hanben. A soft X-ray streak camera with slit length of 30mm[J]. Chinese Journal of Lasers, 1998, B7(2): 120-125.
[43] 廖华, 胡昕, 杨勤劳, 等. 宽量程高时间分辨扫描变像管[J]. 强激光与粒子束, 2011, 23(1):79-82. (Liao Hua, Hu Xin, Yang Qinglao, et al. Wide range and high temporal resolution streak tube[J]. High Power Laser and Particle Beams, 2011, 23(1): 79-82 doi: 10.3788/HPLPB20112301.0079
[44] Gavganen L, Diamant L, Fedorov V, et al. Nanosecond frame cameras based upon proximity focused image intensifiers[C]//Proc of SPIE. 1968, 41: 232-236.
[45] Lieber A J, Sutphin H D. Nanosecond gating of proximity focused channel plate intensifiers[J]. Rev Sci Inst, 1972, 43(1): 104-109. doi: 10.1063/1.1685402
[46] Lieber A J, Sutphin H D. Nanosecond high resolution framing camera[J]. Rev Sci Inst, 1971, 42(11): 1663-1667. doi: 10.1063/1.1684962
[47] Nahrath B, Shakhatre M, Decker G. Nanosecond X-ray pictures recorded with a pulsed channel plate[J]. Rev Sci Instrum, 1976, 1: 88-92.
[48] Eckart M J, Hanks R l, Kilkenny J D, et al. Large-area 200-ps gated microchannel plate detector[J]. Rev Sci Instrum, 1986, 57(8): 2046-2048. doi: 10.1063/1.1138785
[49] Kilkenny J D, Bell P, Hanks R, et al. High speed gated X ray imagers[J]. Rev Sci Instr, 1988, 59(8): 1793-1796. doi: 10.1063/1.1140115
[50] Ladislas J. Microchannel plate detectors[J]. Nuclear Instruments and Methods, 1979, 162: 587-601. doi: 10.1016/0029-554X(79)90734-1
[51] Lieber A J. Picosecond framing camera using a passive microchannel plate[J]. App Opt, 1979, 18(6): 745-746. doi: 10.1364/AO.18.000745
[52] Fehl D L, Chang J, Mendel CW, et al. Five-frame X-ray camera for charged particle inertial confinement fusion studies[J]. Rev Sci Instrum, 1980, 3: 292-296.
[53] Arvid S, Lundy. Ultrafast gating of proximity focused microchannel-plate intensifiers[C]//15th Inter Congr on High Speed Photograph and Photonics.1982,348: 178-189.
[54] Young B K F, Stewartand R E, Woodworth J G. Experiment demonstration of a 100-ps microchannel plate framing camera[J]. Rev Sci Instrum, 1986, 11: 2729-2733.
[55] Bell P M, Killkenny J D, Hanks R, et al. Measurements with a 35 ps gate time microchannel plate camera[C]//Proc of SPIE. 1990, 456: 1346.
[56] Benedetti L R, Bell P M, Bradley D K, et al. Crosstalk in X-ray framing cameras: Effect on voltage, gain, and timing[J]. Rev Sci Instrum, 2012, 83: 10E135. doi: 10.1063/1.4740524
[57] Izumi N, Hall G N, Bell P M, et al. Development of a dual MCP framing camera for high energy X-rays[J]. Rev Sci Instrum, 2014, 85: 11D623. doi: 10.1063/1.4891712
[58] Lugten J B, Brown C G Jr, Piston K W, et al. Optimizing the input and output transmission lines that gate the microchannel plate in a high-speed framing camera[C]//Proc of SPIE. 2015: 95910L.
[59] Kimbrough J R, Bell P M, Bradley D K, et al. Standard design for National Ignition Facility X-ray streak and framing cameras[J]. Rev of Sci Instrum, 2010, 81: 10E530. doi: 10.1063/1.3496990
[60] Koga M, Shiraga H. Gain depletion of X-ray framing camera[J]. Rev of Sci Instrum, 2017, 88: 083514. doi: 10.1063/1.4999757
[61] Nagel S R, Carpenter A C, Park J. The dilation aided single−line−of−sight X−ray camera for the National Ignition Facility: Characterization and fielding[J]. Rev of Sci Instrum, 2018, 89: 10G125. doi: 10.1063/1.5038671
[62] 常增虎, 山冰. 微通道板选通X射线皮秒分幅相机[J]. 光子学报, 1995, 24(6):501-508. (Chang Zenghu, Shan Bing. MCP gated of X-ray framing camera[J]. Acta Photonics, 1995, 24(6): 501-508
[63] 成金秀, 温天舒, 朱宗元, 等. MCP选通X射线皮秒分幅相机在ICF中的应用[J]. 强激光与粒子束, 1996, 8(1): 73-77.

Cheng Jinxiu, Wen Tianshu, Zhu Zongyuan, et al. Multiframe gated microchannel-Rlate X-ray camera used in intertial confinement on ICF faculty[J]. High Power Laser and Particle Beams, 1996, 8(1): 73-77
[64] 成金秀, 杨存榜, 温天舒, 等. 门控MCP软X射线皮秒多分幅相机[J]. 强激光与粒子束, 1999, 11(5): 596-600.

Cheng Jinxiu, Yang Cunbang, Wen Tianshu, et al. MCP gated of soft X-ray multi-frame camera[J]. High Power Laser and Particle Beams, 1999, 11(5): 596-600
[65] Shan Bing, Yanagidaira T, Shimoda K, et al. Quantitative measurement of X-ray images with a gated microchannel plate system in a Z-pinch plasma experiment[J]. Rev Sci Instrum, 1999, 70(3): 1688-1693. doi: 10.1063/1.1149652
[66] Chang Zenghu. Two MCPs gated in cascade for picosecond framing photography[C]//Proc of SPIE. 1995, 2513: 119-124
[67] Nagel S R, Hilsabeck T J, Dymoke-Bradshaw A K L, et al. Investigating high speed phenomena in laser plasma interactions using dilation X-ray imager[J]. Rev Sci Instrum, 2014, 85: 11E504. doi: 10.1063/1.4890396
[68] Cai Houzhi, Fu Wenyong, Liu Jinyuan, et al. Dilation X-ray framing camera and its temporal resolution uniformity[J]. Opt Express, 2019, 27: 2817-2827. doi: 10.1364/OE.27.002817
[69] Cai Houzhi, Fu Wenyong, Liu Jinyuan, et al. Synchronous gating in dilation X-ray detector without 1: 1 image ratio[J]. Opt Express, 2019, 27: 12470-12482. doi: 10.1364/OE.27.012470
[70] Kalibjian R. 100-ps framing-camera tube[J]. Rev of Sci Instrum, 1978, 49(7): 891-896. doi: 10.1063/1.1135594
[71] Ludikov V V, Prokhorov A M, Chevokin V K. A subnanosecond multi-framing camera[J]. Advances in Electronics and Electron Physics, 1998, 74: 239-246.
[72] Lebedev V B, Feldman G G, Kolesov G V, et al. Tests and further development of universal image-converter picosecond camera[C]//Proc of SPIE. 1993, 1801: 528-535.
[73] 牛憨笨, 张焕文, 杨勤劳, 等. 变像管皮秒分幅和飞秒扫描相机的实验研究[J]. 光子学报, 1991, 21(1):11-20. (Niu Hanben, Zhang Huanwen, Yang Qinlao, et al. Experimental study of picosecond framing and femotsecond streak camera[J]. Acta Photonics, 1991, 21(1): 11-20
[74] Feng Jie, Ding Yongkun, Niu Hanben, et al. Improvements of UV/X-ray framing image tube cameras [C]//Proc of SPIE. 1997, 2869: 664-667.
[75] Shiraga H, Heya M, Fujishima A, et al. Laser-imploded core structure observed by using two-dimensional X‐ray imaging with 10 ps temporal resolution[J]. Rev Sci Instrum, 1995, 66(1): 722-724. doi: 10.1063/1.1146482
[76] Heshmat B, Satat G, Barsi C, et al. Single-shot ultrafast imaging using parallax-free alignment with a tilted lenslet array[C]//IEEE, Lasers & Electro-Optics. 2014.
[77] 常增虎, 侯询, 张小秋, 等. X射线皮秒变象管分幅相机研究[J]. 光子学报, 1987, 17(1):1-6. (Chang Zenghu, Hou Xun, Zhang Xiaoqiu, et al. Primary investigation of X ray picosecend frame camera[J]. Acta Photonics, 1987, 17(1): 1-6
[78] 李冀, 屈军乐, 牛憨笨, 等. 取样成像扫描式分幅技术[J]. 强激光与粒子束, 2004, 13(4): 461-466.

Li Ji, Qu Junle, Niu Hanben, et al. Sampling-image streak framing technique[J]. High Power Laser and Particle Beams, 2004, 13(4): 461-466
[79] Shiraga H, Miyanaga N, Heya M, et al. Ultrafast two-dimensional X-ray imaging with X-ray streak cameras for laser fusion research[J]. Rev Sci Instrum, 1997, 68(1): 745-749. doi: 10.1063/1.1147690
[80] Velten A, Willwacher T, Gupta O, et al. Recovering three-dimensional shape around a corner using ultrafast time-of-flight imaging[J]. Nature Communications, 2012, 3(3): 745.
[81] Gao Liang, Liang Jinyang, Li Chiye, et al. Single-shot compressed ultrafast photography at one hundred billion frames per second[J]. Nature, 2014, 516: 74-77. doi: 10.1038/nature14005
[82] Shiraga H. Review of concepts and applications of image sampling on high-speed streak cameras[C]//Proc of SPIE. 2016: 103280R.
[83] https://www.cordin.com/streak.html