摘要: 介绍了利用磁分析器和电子束产生的契伦科夫辐射光诊断直线感应加速器脉冲电子束时间分辨能谱的原理、方法及诊断系统,对中物院2MeV感应叠加型注入器的2kA强流脉冲电子束时间分辨能谱进行实验诊断,并与二极管电压进行对比分析。测得能量约2.2MeV,60ns内最大能量变化为4%。Abstract: Energy variation in pulsed electron beam could result in corkscrew motion of the beam centroid in linear induction accelerator, therefore enlarge and distort the spot size of the accelerator. The method using Cerenkov radiation produced by the electrons passing through the quartz to measure the time resolved energy spectrum is described in this paper. The time resolved energy spectrum diagnostics has been carried out for the pulsed intense electron beam of 2MeV injector at Institute of Fluid Physics of CAEP. Comparison of the experimental results between time resolved energy spectra and diode voltage waveforms are given and analysed. The measured energy is about 2.2MeV, the maximum energy variation in 60ns is 4%。
-