组合式片状放大器热恢复模拟研究
-
摘要: 针对组合式片状放大器工作时的热量沉积特性,分析了氙灯箱和片腔的冷却过程,重点研究了激光介质钕玻璃片的热恢复过程。初步的热分析表明,为每支氙灯提供4.7×10-3m3/s的冷却气量以及为每个片腔提供7.6×10-3m3/s的冷却气量时能够满足装置4小时一发的运行频率要求。Abstract: We have investigated numerically the thermal recovery of the large aperture multi0segment amplifiers in the paper. With AMPHR3D, which is a thre-dimensional transient finite element heat transfer code, the temperature of Na:glass slab is investigated in detial, Preliminary thermal analysis indicates that active cooling with 4.7 10- 3m3s- 1 per flash lamp in lamp cassette cooperated with 7.6 10- 3m3s- 1 per slab cavity is sufficient to meet the 4 hour shot period of the lser system.
-
Key words:
- disk amplifiers /
- therml recovery /
- numericl simulation
点击查看大图
计量
- 文章访问数: 1983
- HTML全文浏览量: 189
- PDF下载量: 449
- 被引次数: 0