TEA CO2激光器涡流管同轴非稳腔光束质量
Beam quality of unstable resonator of TEA CO2 coaxial output laser with vortex tube cooling system
-
摘要: 为改善TEA CO2同轴非稳腔激光器输出光束质量,采用涡流管低温气流冷却窗口及凸镜,实验实时测量了单脉冲平均能量18.3 J、在不同工作频率下及是否采用涡流管冷却情况下的光束模式,并计算出衍射极限倍数因子值。激光器工作频率3 Hz,连续运行300 s,没有涡流管冷却时衍射极限倍数因子值由3.52变化到6.94;采用涡流管冷却后,该值仅由3.50变化到3.88。
-
关键词:
- TEA CO2激光器 /
- 同轴非稳腔 /
- 涡流管 /
- 光束质量
Abstract: The beam quality of unstable resonator of TEA CO2 coaxial output laser is deteriorated remarkably by the thermal accumulation of the output coupler. In order to improve the beam quality, a vortex tube cooling system of output coupler was adopted. The divergence angle was measured at an average pulse energy of 18.3 J under condition of different frequency with and without using the vortex tube cooling system at real time, and the timesdiffractionlimited factor was studied. The results show that the times diffractionlimited factor was changed from 3.52 to 6.94 without the vortex tube cooling system and from 350 to 3.88 with the cooling system at 3 Hz during an operating time of 300 s.-
Key words:
- tea co2 laser /
- unstable resonator /
- vortex tube /
- beam quality
-

计量
- 文章访问数: 3011
- HTML全文浏览量: 283
- PDF下载量: 502
- 被引次数: 0