Tesla变压器与Blumlein线一体化装置设计
Integrative device design of Tesla transformer with Blumlein pulse forming line
-
摘要: 介绍了Tesla变压器与Blumlein线一体化装置的基本原理,设计了Tesla变压器及Blumlein线的参数。对装置中绝缘薄弱点进行了电场分析,结果表明:Blumlein线结构设计满足变压器油中绝缘的要求,可以保证装置安全稳定运行。最后对整个装置进行了全电路模拟,模拟结果表明:形成线充电电压可达1.37 MV,此时,50 Ω上可得到脉冲电压的辐值约为1.4 MV,脉宽约为40 ns,满足设计要求。Abstract: The principle of an integrative denvice of Tesla transformer with Blumlein pulse forming line(PFL) has been introduced in the paper. The parameters of the Telsa transformer and the Blumlein PFL were designed, while the electrical field distribution of the device was analyzed. The results show that the structure of the PFL satisfies the insulation condition of transformer oil, ensuring the device’s safe operation. Finally, the full circuit analysis of the device is simulated by Pspice. It is shown that the charge voltage of the Blumlein PFL is up to 1.37 MV. In this condition, the output voltage of 50 Ω load is 1.4 MV with 40 ns pulse width, which meets the design requirement.
-
Key words:
- tesla transformer /
- blumlein line /
- integrative device /
- electric field
点击查看大图
计量
- 文章访问数: 1973
- HTML全文浏览量: 240
- PDF下载量: 555
- 被引次数: 0