感应电压叠加器驱动阳极杆箍缩二极管型脉冲X射线源
Pulsed X-ray source based on inductive voltage adder and rod pinch diode for radiography
-
摘要: 介绍了自行研制的用于闪光照相且基于感应电压叠加器和阳极杆箍缩二极管的X射线源的组成、结构和主要参数。输出电压3 MV的Marx发生器给阻抗7.8 Ω水介质脉冲形成线充电,产生脉宽约70 ns,电压约1 MV的高功率脉冲,经过峰化开关和预脉冲开关后分成3路馈入三级感应电压叠加器感应腔进行电压叠加,感应电压叠加器次级采用真空绝缘传输线,阻抗从40 Ω变成60 Ω,驱动阳极杆箍缩二极管,二极管阴极为石墨,阳极为直径1.2 mm的钨杆,石墨阴极产生的电子束在电流自磁场作用下发生箍缩,轰击阳极,产生小焦斑脉冲X射线。该装置在Marx充电电压为±35 kV时,二极管电压约2.0 MV,二极管电流约为50 kA,半高宽约80 ns;X射线半高宽约为40 ns,剂量约为28 mGy,焦斑约为0.95 mm。利用该X射线源拍摄到了炸药爆炸产生的层裂碎片不同飞行时间的图像。Abstract: The pulsed X-ray source based on the inductive voltage adder (IVA) and rod pinch diode (RPD) is developed, and its configuration and main parts and output parameters are introduced in detail. The Marx generator with 3.3 MV charges the water pulsed forming lines with 7.8 Ω and produces the high power pulse of 70 ns width with about 1 MV feeding the three IVA cells in parallel through the peaking water switch and the pre-pulse oil switch. The secondary of IVA adopts the vacuum insulation transmission line (VITL) with the impedance from 40 Ω up to 60 Ω, driving the RPD isolated from the output terminal of IVA for 2 m VITL. The diameter of the graphite cathode of RPD is 12 mm, and the diameter of the tungsten anode rod is 1.2 mm. The electron beam from the cathode is pinched to the tip of t
-
Key words:
- inductive voltage adder /
- rod pinch diode /
- radiography /
- spall /
- pulsed x-ray source
计量
- 文章访问数: 2377
- HTML全文浏览量: 326
- PDF下载量: 637
- 被引次数: 0