摘要: 在“星光-Ⅱ”激光装置上进行了双预脉冲驱动类氖铬X射线激光实验,介绍了实验方法和实验结果,并对结果进行了简短讨论。由于目前“星光”装置输出能量较低,所进行的双预脉冲驱动未能显著提高X射线激光强度,改变预脉冲幅度时X射线激光强度也未有显著变化。利用MED103程序进行了模拟计算,其结果与实验结果一致。Abstract: The experimental investigation on X-ray laser is performed using two driving prepulses at the "Xingguang-Ⅱ" device. The experimental method and result are reported. The experiment didn't find remarkable enhancement of the output energy of X-ray laser using two prepulses than using one prepulse. One of the reasons maybe the driving laser energy is too low. Utilizing MED103 procedure to imitate calculation, it gives the same result as the experiment.
-