新型宽谱电磁脉冲试验系统
Novel wide-spectrum electromagnetic pulse test system
-
摘要: 研制了一套新型宽谱电磁脉冲试验系统,该系统采用全电感隔离型重复频率Marx发生器产生高压冲击脉冲,经双极脉冲形成线馈入宽带天线进行宽谱辐射。介绍了发生器工作原理和双极脉冲形成原理。实验结果表明:发生器输出脉冲电压500 kV,脉冲前沿20 ns,重复频率20 Hz,宽谱辐射因子195 kV,辐射中心频率200 MHz,频谱宽度37%。该试验系统结构紧凑、操作灵活,并具有方位辐射方向360°旋转和运程控制等功能。Abstract: A novel wide-spectrum electromagnetic pulse test system is designed. This system makes use of all-inductive isolated repetition frequency Marx generator to produce high-voltage pulse which is then fed into broadband antenna for wide-spectrum radiation through bipolar pulse-forming line. Working principle of this generator and forming principle of bipolar pulse are both introduced. By means of experiment, following qualifications of the system is concluded, output pulse voltage 500 kV, front edge 20 ns, repetition frequency 20 Hz, wide spectrum radiation factor 195 kV, center radiation frequency 200 MHz, spectrum width 37%. Test system has compact configuration and flexible operation and has also 360 degree rotation at azimuth radiation and the remote control function.
-