同轴安装避免引燃管自闪
Avoiding ignitron prefire with a coaxial structure
-
摘要: 分析了高功率固体激光能源系统新型放电回路中引燃管的自闪原因,提出引燃管同轴安装结构,利用同轴结构的负反馈作用,把放电电流控制在引燃管中央;同时利用同轴结构的电场屏蔽作用,进一步减少水银在管壁的凝结。在4×2×3片状放大器2 000发次的运行中,引燃管没有发生自闪现象。Abstract: This paper analyzes the mechanism that ignitron prefires when it is used in new discharge circuit of power conditioning system for high power laser. The performance of ignitron is improved with a coaxial structure. The coaxial structure not only controls discharge current flowing through the center of ignitron but also shields the electric field produced by the ignitron. The ignitrons have successfully run over 2 000 shots in 4×2×3 amplifier system without prefire.
-
Key words:
- high power laser /
- power conditioning system /
- iignitron /
- prefire /
- coaxial structure
计量
- 文章访问数: 2116
- HTML全文浏览量: 371
- PDF下载量: 610
- 被引次数: 0