Z-pinch X射线时间分辨多幅图像诊断系统
Time resolved Xray image diagnostic system for Zpinch
-
摘要: 介绍了为“强光一号”设计的ns级时间分辨软X射线多幅图像诊断系统,分析了系统的主要性能指标,给出并分析了利用该系统诊断“强光一号”高功率脉冲Zpinch等离子体辐射源的最新的实验结果。Abstract: A high speed gated soft Xray multiframe image diagnostic system was developed for QiangGuangI generator, which was operated with a peak current of 1.5MA and a rise time of 80ns. In the system, a gated fourframe (3~5ns gate, 5~20ns separation) Xray camera, used in conjunction with a set of filtered pinholes was employed. Pinholes of 0.1mm and 0.3mm were used, which gave a spatial resolution of 0.56mm and 1mm, respectively. The pinholes were filtered with 2μm aluminized mylar. The system was sensitive to 150~300eV photons and to those greater than 550eV. Finally the last experimental results measured by this system in QiangGuangI generator were discussed.
-
Key words:
- framing camera /
- plasma diagnostics /
- soft xray /
- zpinch
计量
- 文章访问数: 3146
- HTML全文浏览量: 315
- PDF下载量: 807
- 被引次数: 0