Design and analysis of positron emission tomography cyclotron RF cavity
-
摘要: 根据正电子发射断层显像(PET)回旋加速器的物理要求与实际情况,确定了PET回旋高频双腔体的具体设计方案。在加速电压比较高的要求下,充分利用有限的空间,设计1/4波长线的异型覆面的竖腔结构腔体,采用短路片与移动电容板双调谐结构,满足了频率调谐要求;同时获得较高的品质因数,达到了物理设计要求的加速电压。利用Microwave Studio CST程序对腔体的Q0值、热分布、功率损耗、微调电容做了详细的分析与计算;对实际测量值与仿真计算值进行了对比,并对产生的误差进行了分析和讨论。腔体电压实际测量值达到50 kV以上,频率稳定度达到设计指标1.010-6/d。;Abstract: According to the physical requirements and the actual situation of Positron Emission Tomography (PET) cyclotrons at Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS), a new compact RF cavity with a quarter wave resonator structure and a profiled cover was designed with high accelerated e-field gradient. Additionally, a special dual tuning structure with a short-plate and a movable capacitor plate was designed to meet the requirements of complicated tuning operation mode. The simulated results from Microwave Studio (CST) showed that the design obtained a high quality factor and reached a rated accelerated voltage. The electro-magnetic analysis was carried out, and the power loss tolerance and the thermal distribution were calculated. A prototype cavity was fabricated and measured in January, 2013, and the tested results indicated that the accelerated voltage was higher than 50 kV and the frequency stability was 10-6/d, both of them reached the original design specification. This proves that the measured results agree well with the simulated ones. All detailed simulations and measurements were analyzed and discussed.
-
Key words:
- cyclotron /
- cavity design /
- quality factor /
- stability
点击查看大图
计量
- 文章访问数: 1223
- HTML全文浏览量: 219
- PDF下载量: 473
- 被引次数: 0