金属腔内场线耦合干扰敏感性

周小兰 闫丽萍 刘强 赵翔 周海京

周小兰, 闫丽萍, 刘强, 等. 金属腔内场线耦合干扰敏感性[J]. 强激光与粒子束, 2016, 28: 023201. doi: 10.11884/HPLPB201628.023201
引用本文: 周小兰, 闫丽萍, 刘强, 等. 金属腔内场线耦合干扰敏感性[J]. 强激光与粒子束, 2016, 28: 023201. doi: 10.11884/HPLPB201628.023201
Zhou Xiaolan, Yan Liping, Liu Qiang, et al. Susceptibility of field coupling to transmission line inside metallic enclosure[J]. High Power Laser and Particle Beams, 2016, 28: 023201. doi: 10.11884/HPLPB201628.023201
Citation: Zhou Xiaolan, Yan Liping, Liu Qiang, et al. Susceptibility of field coupling to transmission line inside metallic enclosure[J]. High Power Laser and Particle Beams, 2016, 28: 023201. doi: 10.11884/HPLPB201628.023201

金属腔内场线耦合干扰敏感性

doi: 10.11884/HPLPB201628.023201
详细信息
    通讯作者:

    闫丽萍

Susceptibility of field coupling to transmission line inside metallic enclosure

  • 摘要: 研究了金属腔内电磁场与单导线耦合对线两端部件产生干扰的敏感性问题。利用并矢格林函数计算腔内场分布, 利用Agrawal模型计算获得导线两端负载的干扰响应, 从腔体尺寸、内部干扰源位置及导线位置三个方面分析了建模的微小变化对导线负载干扰的影响。结果表明, 腔体尺寸的微小变化会带来负载干扰响应的很大变化, 在谐振点处该影响尤其明显;腔内干扰源位置的微小变化可能会带来负载干扰响应的巨大变化;干扰响应对导线距离金属腔壁高度的微小变化不敏感, 但单导线位置的微小变化可能带来负载干扰的较大变化。
  • [1] 刘尚合, 武占成, 张希军. 电磁环境效应及其发展趋势[J]. 国防科技, 2008, 29(1):1-6.Liu Shanghe, Wu Zhancheng, Zhang Xijun. The effect of electromagnetic enviorment and trend. National Defense Science and Technology,2008, 29 (1):1-6.

    [2] 王天乐, 闫丽萍, 赵翔, . 包含非线性组件的系统级电磁效应分析方法[J]. 强激光与粒子束, 2014, 26: 073204.(Wang Tianle, Yan Liping, Zhao Xiang, et al.System-level analysis method of electromagnetic effects on an electronic system containing nonlinear components. High Power Laser and Paticle Beams,2014, 26:073204)

    [3] 史记元, 罗建书, 倪谷炎, . 孔缝腔体内多导体传输线的耦合响应[J]. 强激光与粒子束, 2011, 23(3):849-850.(Shi Jiyuan, Luo Jianshu, Ni Guyan, et al.Coupling onto wires enclosed in cavity with aperture. High Power Laser and Paticle Beams, 2011, 23(3):849-850)

    [4] 高雪莲, 赵磊, 金芳, . 一种计算双层带缝屏蔽腔内置传输线响应的混合方法[J]. 强激光与粒子束, 2015,27: 083206.(Gao Xuelian, Zhao Lei, Jin Fang, et al.Hybrid method to calculate response of transmission lines in double-layer shielding cavity with apertures.High Power Laser and Paticle Beams,2015, 27: 083206)

    [5] Boutar A, Reineix A, Guiffaut C, et al. An efficient analytical method for electromagnetic field to transmission line coupling into a rectangular enclosure excited by an internal source[J]. IEEE Trans Electromagn Compat, 2015, 57(3): 565-573.

    [6] Boutar A, Reineix A, Guiffaut C, et al. A very efficient analytical approach for electromagnetic field to transmission line coupling in shielded enclosure[C]. Inter Sympos Electromagn Compat, 2013:270-275.

    [7] Edelvik F. A new technique for accurate and stable modeling of arbitrarily oriented thin wires in the FDTD method[J]. IEEE Trans Electromagn Compat,2003, 45(2): 416-423.

    [8] Paletta L, Parmantier J P, Issac F, et al. Susceptibility analysis of wiring in a complex system combining a 3-D solver and a transmission-line network simulation[J]. IEEE Trans Electromagn Compat, 2002, 44(2): 309-317.

    [9] Spadacini G, Pignari S, Marliani F. Closed-form transmission line model for radiated susceptibility in metallic enclosures[J]. IEEE Trans Electromagn Compat,2005, 47(4): 701-708.

    [10] Tkachenko S V, Rambousky R, Nitsch J B. Electromagnetic field coupling to a thin wire located symmetrically inside a rectangular enclosure[J]. IEEE Trans Electromagn Compat,2013, 55(2): 334-341.

    [11] Hill D A. Electromagnetic fields in cavities[M]. New Jersey: John Wiley & Sons, 2009.  

    [12] Rahmat–Samii Y. On the question of computation of the dyadic green's function at the source region in waveguides and cavities[J]. IEEE Trans Microwave Theory Techn, 1975, 23(9): 762-765.

    [13] Tesche F M, Ianoz M, Karlsson T. EMC analysis methods and computational models[M]. New Jersey: John Wiley & Sons, 1997.

    [14] Agrawal A K, Price H J, Gurbaxani S H. Transient response of multiconductor transmission lines excited by a nonuniformelectromagnetic field[J]. IEEE Trans Electromagn Compat, 1980, 22 (2): 119-129.

    [15] Tesche F M, Liu T K. Application of multiconductor transmission line network analysis to internal interaction problems[J]. Electromagnetics, 1986, 6(1): 1-20.
  • 加载中
计量
  • 文章访问数:  1683
  • HTML全文浏览量:  292
  • PDF下载量:  379
  • 被引次数: 0
出版历程
  • 收稿日期:  2015-09-06
  • 修回日期:  2015-11-17
  • 刊出日期:  2016-02-15

目录

    /

    返回文章
    返回