High energy X-ray spot size measurement with rollbar
-
摘要: 应用于高能闪光X光照相技术的X射线源焦斑大小是闪光照相装置的关键参数, 直接影响成像的分辨能力。由于高能X射线的强穿透性和强辐射环境, 给焦斑测量带来一定困难。介绍了一种间接测量方法, 采用滚边装置(rollbar)成像得到X射线源的边扩展函数, 微分后得到光源的线扩展函数并计算调制传递函数(MTF), 而后从MTF为0.5所对应的空间频率之值确定出光源的光斑大小。给出了神龙二号加速器电子束聚焦调试实验中得到的X射线焦斑测量结果, 分析影响测量结果的因素并提出了解决方法。Abstract: The X-ray spot size is a critical parameter for flash radiography facility which degrades resolution in the flash radiography. It is difficult to measure the X-ray spot size in the condition of intense radiation and its penetrability. This paper describes a rollbar used to measure the X-ray focal spot size. The edge spread function(ESF), line spread function(LSF) and modulation transfer function(MTF) of the X-ray spot are obtained from the rollbar image data, and the X-ray spot size is determined by the MTF. In the experiment of Dragon-Ⅱ linear induction accelerator downstream and target, the X-ray spot size is measured and the results are analyzed.
-
Key words:
- high energy X-ray /
- spot size /
- modulation transfer function /
- rollbar