Shielding calculations of PWR using JSNT code
-
摘要: 反应堆屏蔽计算是评估核电站安全性能的基础,是指导电站设计、运行的重要手段之一。JSNT程序是中物院高性能数值模拟软件中心研制的大规模并行离散纵标输运程序,具有较高的计算精度和计算效率。利用JSNT程序对某压水堆进行了建模计算,给出了中子通量密度的分布结果,并与实验测量值进行了对比。对比结果显示:无论是采用S8计算还是S16计算,计算结果都能满足工程要求;相比S8而言,采用S16计算可以显著提高计算精度,能够将某些测点处的相对误差降至1%以内。Abstract: Reactor shielding calculations is the foundation for assessing nuclear plant safety performance. It is also an important method to provide guidelines for constructions and operations of nuclear plant. JSNT is a massively parallel discrete ordinates transport code developed by CAEP software center for high performance numerical simulation, with high simulation precision and efficiency. In this paper, a commercial PWR has been modeled and simulated using JSNT code. Flux distributions are obtained and compared with experimental measuring results. Comparisons show that results obtained by both S8 and S16 calculations could satisfy engineering demand. Moreover, in comparison to S8 calculation, S16 could improve the calculation precision significantly and decrease relative errors of some detectors under 1%.
-
Key words:
- shielding calculations /
- SN method /
- parallel calculations /
- quadrature sets
期刊类型引用(4)
1. 叶耀新,赵均,包鹏飞,于超,江娉婷. 压水堆辐照监督理论计算的加速方法及验证. 核动力工程. 2024(06): 30-38 . 百度学术
2. 王事喜,吴明宇,周培德. 基于三维离散纵标方法的大型钠冷快堆一回路~(24)Na源项计算研究. 核科学与工程. 2021(03): 615-620 . 百度学术
3. 杨超,程汤培,邓力,付元光,温丽丽. 三维并行程序JSNT对HBR-2装置的屏蔽计算与分析. 原子能科学技术. 2019(02): 250-255 . 百度学术
4. 赵传奇,胡文超,刘健,靖剑平. 基于三维输运方法的压水堆主冷却剂~(16)N源项计算分析. 核安全. 2017(02): 69-73+79 . 百度学术
其他类型引用(2)
-

计量
- 文章访问数: 1857
- HTML全文浏览量: 364
- PDF下载量: 276
- 被引次数: 6