Design and experiments of the 200 keV pulse X-ray source based on PFN-Marx technology
-
摘要: 基于PFN-Marx技术路线研制了200 kV脉冲驱动源,采用了超前触发技术,实现了在40 Ω水电阻负载上输出电压约200 kV、前沿约25 ns、脉冲宽度约62 ns的脉冲高压。设计了工作电压为200 kV的“Washer-Needle”型二极管,在二极管电压210 kV、电流5 kA条件下,输出X射线脉冲宽度约40 ns,X射线焦斑直径1.2 mm,1 m处照射剂量约15 mR。Abstract: The 200 keV X-ray pulser has a good surface density resolution when being used in the imaging diagnosis of high speed and low density regions in ejecta. Heuce it has become one of the important technical diagnostics methods of ejecta. This papper develops a 200 keV pulse driver based on the PFN-Marx technology. Using a pre-trigger method, the 200 kV pulse of a 62 ns width and a 25 ns rise time is produced on the 40 Ω water resistance, A “Washer-Needle” type diode which can work under 200 kV voltage is also designed. When the diode operating voltage is 210 kV, the pulser outputs the X-ray pulse of a 40 ns width, a 1.2 mm spot size and a 15 mR dose at 1 m distance .
-
Key words:
- pulse X-ray source /
- 200 keV /
- PFN-Marx /
- pulsed power /
- flash X-ray radiography
-
表 1 脉冲驱动源实验
Table 1. The experiment of the pulsed power source
shot charge voltage/kV load voltage/kV rise time/ns pulse width/ns 1 ±31 205.6 21 65 2 ±30 202.9 19 63 3 ±30 191.7 21 61 4 ±30 191.7 20 61 5 ±31 224.3 20 60 6 ±30 192.3 20 64 7 ±31 203 19 64 8 ±30 192.2 20 62 -
[1] 吴红光, 曹科峰, 梁川, 等. 150 kV脉冲X光机[J]. 强激光与粒子束, 2010, 22(4):941-944. (Wu Hongguang, Cao Kefeng, Liang Chuan, et al. 150 kV pulsed X-ray system[J]. High Power Laser and Particle Beams, 2010, 22(4): 941-944 doi: 10.3788/HPLPB20102204.0941Wu Hongguang, Cao Kefeng, Liang Chuan, et al. 150 kV pulsed X-ray system[J]. High Power Laser and Particle Beams, 2010, 22(4): 941-944 doi: 10.3788/HPLPB20102204.0941 [2] 梁川, 席璐璘, 周林, 等. 便携式150 kV闪光X光源研制及应用[J]. 强激光与粒子束, 2014, 26:045033. (Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033 doi: 10.11884/HPLPB201426.045033Liang Chuan, Xi Lulin, Zhou Lin, et al. Investigation and application of a portable 150 kV flash X-ray system[J]. High Power Laser and Particle Beams, 2014, 26: 045033 doi: 10.11884/HPLPB201426.045033 [3] Morgan D V, Grover M, Macy D, et al. Observations of shock-loaded tin and zirconium surfaces with single-pulse X-ray diffraction[J]. Powder Diffraction, 2010, 25(2): 138-142. doi: 10.1154/1.3402838 [4] Gupta Y M, Zimmerman K A, Rigg P A, et al. Experimental developments to obtain real-time X-ray diffraction measurements in plate impact experiments[J]. Review of Scientific Instruments, 1999, 70(10): 4008-4014. doi: 10.1063/1.1150026 [5] 田慧, 栗保明. 用于弹道研究的脉冲X射线诊断系统[J]. 试验技术与试验机, 2008, 48(2):62-66. (Tian Hui, Li Baoming. A flash X-ray diagnosis system for ballistics study[J]. Test Technology and Testing Mechine, 2008, 48(2): 62-66Tian Hui, Li Baoming. A flash X-ray diagnosis system for ballistics study[J]. Test Technology and Testing Mechine, 2008, 48(2): 62-66 [6] 张小强, 赵光义, 周林, 等. 500 kV亚纳秒脉冲X光机研制[J]. 强激光与粒子束, 2018, 30:025004. (Zhang Xiaoqiang, Zhao Guangyi, Zhou Lin, et al. Design of 500 kV sub-nanosecond pulsed X-ray generator[J]. High Power Laser and Particle Beams, 2018, 30: 025004 doi: 10.11884/HPLPB201830.170389Zhang Xiaoqiang, Zhao Guangyi, Zhou Lin, et al. Design of 500 kV sub-nanosecond pulsed X-ray generator[J]. High Power Laser and Particle Beams, 2018, 30: 025004 doi: 10.11884/HPLPB201830.170389 [7] Zellner M B, Grover M, Hammerberg J E, et al. Effects of shock-breakout pressure on ejection of micron-scale material from shocked tin surfaces[J]. Journal of Applied Physics, 2007, 102: 013522. doi: 10.1063/1.2752130 [8] Zellner M B, McNeil W V, Hammerberg J E, et al. Probing the underlying physics of ejecta production from shocked Sn samples[J]. Journal of Applied Physics, 2008, 103: 123502. doi: 10.1063/1.2939253 [9] Monfared S K, Buttler W T, Frayer D K, et al. Ejected particle size measurement using Mie scattering in high explosive driven shockwave experiments[J]. Journal of Applied Physics, 2015, 117: 223105. doi: 10.1063/1.4922180 [10] Morgan D V, Macy D, Stevens G. Real-time X-ray diffraction measurements of shocked polycrystalline tin and aluminum[J]. Review of Scientific Instruments, 2008, 79: 113904. doi: 10.1063/1.3030855 [11] Johnson Q, Mitchell A C. Flash X-ray tube for diffraction studies on a two-stage light-gas gun[J]. Review of Scientific Instruments, 1980, 51(6): 741-749. doi: 10.1063/1.1136306 [12] Boyer C N, Holland G E, Seely J F. Intense source of nanosecond duration 10-keV to 250 keV X rays[C]//Proceedings of SPIE 4781, Advances in Laboratory-Based X-Ray Sources and Optics III. 2002: 42-53.