Optimization and test of optical precision mount with large aperture
-
摘要: 针对大功率激光检测技术发展中精密光学调整架存在的刚度不足的问题,设计了一种适合装调大口径光学镜片的精密光学调整架结构,并建立其力学模型,分析其动力学性能,通过420 mm大口径球关节调整架结构俯仰模态理论的分析和实验测试数据之间对比,找出导致调整架结构谐振频率变差的原因。采用优化设计后的大口径调整架第一阶俯仰模态的频率为157.788 Hz,能够很好满足在强振源下的工作需要。Abstract: Considering the natural frequency weakening of a high power lasers optical precision mount matching with large aperture, the paper states an optical precision mount with large aperture, with its mechanical model built and its dynamic abilities analyzed. By contrasting theoretical analysis and test data of the optical precision mount with a 420 mm mirror, the reasons for natural frequency weakening have been seeked. The optimized structure of the optical precision mount with large aperture has a first-mode elastomer pitching swing frequency of 157.788 Hz, which could meet the working condition under the intense vibration.
-
Key words:
- precision optics /
- mount /
- mechanical model /
- resonant frequency /
- vibration test
点击查看大图
计量
- 文章访问数: 1749
- HTML全文浏览量: 214
- PDF下载量: 309
- 被引次数: 0