Li Xiqin, Ding Mingjun, Wu Hongguang, et al. Development of low jitter fast fall time and repetitive high voltage pulsed trigger[J]. High Power Laser and Particle Beams, 2014, 26: 095001. doi: 10.11884/HPLPB201426.095001
Citation:
Li Xiqin, Ding Mingjun, Wu Hongguang, et al. Development of low jitter fast fall time and repetitive high voltage pulsed trigger[J]. High Power Laser and Particle Beams, 2014, 26: 095001. doi: 10.11884/HPLPB201426.095001
Li Xiqin, Ding Mingjun, Wu Hongguang, et al. Development of low jitter fast fall time and repetitive high voltage pulsed trigger[J]. High Power Laser and Particle Beams, 2014, 26: 095001. doi: 10.11884/HPLPB201426.095001
Citation:
Li Xiqin, Ding Mingjun, Wu Hongguang, et al. Development of low jitter fast fall time and repetitive high voltage pulsed trigger[J]. High Power Laser and Particle Beams, 2014, 26: 095001. doi: 10.11884/HPLPB201426.095001
Design theory and method was discussed about the low jitter fast fall time and repetitive high voltage pulsed trigger. The trigger met the following design specifications: pulse voltage up to 20 kV, fall time less than 10 ns, width more than 500 ns and jitter less than 1 ns. Using program control and manual control, repetitive model and single model were got respectively. The finally high voltage pulse was received through IGBT and VE4141 thyratron. The experimental results testified the feasibility of the design theory and method.