Calculation of pulse current of high power converter

doi: 10.11884/HPLPB201931.180283
  • Received Date: 2018-10-23
  • Rev Recd Date: 2019-01-21
  • Publish Date: 2019-03-15
  • In order to meet the requirements of nuclear fusion experiments, the converter is required in the design of the next generation tokamak to output instantaneous high-intensity pulsed current for providing type test dynamic and thermal stability in large electrical equipment. In this paper, a method of equating the impedance of the power supply system to the secondary side of the transformer and combining the voltage change relationship at both ends of the converter is presented. The total output current of several converters is obtained by calculation in different electrical parameters. The calculating process and results of electrical parameters meeting the requirements are given when the output current is 1 MA. The results are the limit condition under the given parameter, which makes the minimum design threshold in the high-power converter impulse current design, and lays the foundation for the following converter device selection and structure design.
  • loading
  • [1]
    袁红文. ITER极向场变流器运行性能分析[D]. 合肥: 中国科学院合肥物质科学研究院, 2014: 15-25.

    Yuan Hongwen. Study on the operational performance of ITER poloidal field converter system. Hefei: Hefei Institutes of Physical Science, Chinese Academy of Sciences, 2014: 15-25
    [2]
    Yuan Hongwen, Fu Peng, Gao Ge, et al. On the circulating current control of ITER poloidal field converter[J]. Journal of Fusion Energy, 2014, 33(3): 269-274. doi: 10.1007/s10894-013-9662-5
    [3]
    Fu Peng, Gao Ge, Song Zhiquan, et al. Preliminary design of the poloidal field AC/DC converter system for the ITER coil power supply[J]. Fusion Science and Technology, 2013, 64(4): 741-747. doi: 10.13182/FST13-A24094
    [4]
    Fu Peng, Liu Zhengzhi, Gao Ge, el al. Power supply system of EAST superconducting tokamak[C] //Proc of ICIEA. 2010: 457-462.
    [5]
    高格, 傅鹏, 黄大华, 等. ±15kA四象限运行变流电源的研制[J]. 电力电子技术, 2005, 39(2): 72-74. https://www.cnki.com.cn/Article/CJFDTOTAL-DLDZ20050200Q.htm

    Gao Ge, Fu Peng, Huang Dahua, et al. Manufacture of rectifier with output current of ±15 kA. Power Electronics, 2005, 39(2): 72-74 https://www.cnki.com.cn/Article/CJFDTOTAL-DLDZ20050200Q.htm
    [6]
    高格, 傅鹏. 可控并联十二脉波四象限运行整流电源的研制[J]. 电工技术学报, 2004, 19(7): 16-20. https://www.cnki.com.cn/Article/CJFDTOTAL-DGJS200407003.htm

    Gao Ge, Fu Peng. Manufacture of parallel connection, 12-pulse rectifier with 4-quardant running mode. Transactions of China Electrotechnical Society, 2004, 19(7): 16-20 https://www.cnki.com.cn/Article/CJFDTOTAL-DGJS200407003.htm
    [7]
    陈鹏. TOKAMAK极向场变流器的结构设计[D]. 合肥: 中国科学院合肥物质科学研究院, 2011: 20-32.

    Chen Peng. The mechanical design of TOKAMAK poloidal field (PF) AC-DC converters. Hefei: Hefei Institutes of Physical Science, Chinese Academy of Sciences, 2011: 20-32
    [8]
    Chen Xiaojun, Fu Peng, Gao Ge, et al. ITER poloidal field converter fault analysis[J]. Journal of Fusion Energy, 2015, 34(2): 177-182. doi: 10.1007/s10894-014-9772-8
    [9]
    Wang Peng, Fu Peng, Song Zhiquan, et al. A new structure based on dynamic stability analysis of external bypass for ITER poloidal field converter[J]. Journal of Fusion Energy, 2015, 34(1): 116-121. doi: 10.1007/s10894-014-9769-3
    [10]
    梁勖, 赵读亮, 林颖, 等. 基于可控LC串联谐振的高重频高精度脉冲充电电源[J]. 高电压技术, 2018, 44(9): 3022-3027. https://www.cnki.com.cn/Article/CJFDTOTAL-GDYJ201809035.htm

    Liang Xu, Zhao Duliang, Lin Ying, et al. High repetition rate and high accuracy capacitor charging pulse power supply based on controllable LC series resonance. High Voltage Engineering, 2018, 44(9): 3022-3027 https://www.cnki.com.cn/Article/CJFDTOTAL-GDYJ201809035.htm
    [11]
    伍友成, 刘高旻, 戴文峰, 等. 轻小型高电压大电流脉冲电源研制[J]. 高电压技术, 2018, 44(9): 3016-3021. https://www.cnki.com.cn/Article/CJFDTOTAL-GDYJ201809034.htm

    Wu Youcheng, Liu Gaomin, Dai Wenfeng, et al. Design of small-size high voltage and large current pulsed power source. High Voltage Engineering, 2018, 44(9): 3016-3021 https://www.cnki.com.cn/Article/CJFDTOTAL-GDYJ201809034.htm
    [12]
    Ryoo H J, Jang S R, Jin Y S, et al. Design of high voltage capacitor charger with improved efficiency, power density and reliability[J]. IEEE Trans Dielectrics and Electrical Insulation, 2013, 20(4): 1076-1084. doi: 10.1109/TDEI.2013.6571420
    [13]
    刘芬, 胡安, 刘德志. 考虑了交流侧电阻的三相全控整流电路的计算[J]. 船电技术, 2005, 25(1): 35-38. https://www.cnki.com.cn/Article/CJFDTOTAL-CDJI20050100A.htm

    Liu Fen, Hu An, Liu Dezhi. Calculation of three-phase fully-controlled rectifier circuit considering AC-side electric resistance. Marine Electric and Electronic Technology, 2005, 25(1): 35-38 https://www.cnki.com.cn/Article/CJFDTOTAL-CDJI20050100A.htm
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(5)  / Tables(2)

    Article views (1264) PDF downloads(77) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return