Wu Hongguang, Wang Xiao, Li Xiqin, et al. 300 kV high-voltage pulse generator[J]. High Power Laser and Particle Beams, 2012, 24: 715-718. doi: 10.3788/HPLPB20122403.0715
Citation:
Wu Hongguang, Wang Xiao, Li Xiqin, et al. 300 kV high-voltage pulse generator[J]. High Power Laser and Particle Beams, 2012, 24: 715-718. doi: 10.3788/HPLPB20122403.0715
Wu Hongguang, Wang Xiao, Li Xiqin, et al. 300 kV high-voltage pulse generator[J]. High Power Laser and Particle Beams, 2012, 24: 715-718. doi: 10.3788/HPLPB20122403.0715
Citation:
Wu Hongguang, Wang Xiao, Li Xiqin, et al. 300 kV high-voltage pulse generator[J]. High Power Laser and Particle Beams, 2012, 24: 715-718. doi: 10.3788/HPLPB20122403.0715
A 300 kV high voltage pulse generator designed according to the principle of bipolar charged Marx generator is introduced, which serves as the driving of X-ray system. Low jitter spark gap switches and low inductance ceramic capacitors are used in the pulse generator to shorten the risetime and pulse width of the output pulse. The generator can get a pulse with amplitude of 200 to 300 kV and pulse width less than 100 ns on the 75 resistance load. It features stable performance, compact structure, and is easy to operate.