The fusion reaction history is valuable information for inertial confinement fusion experiment research. The Geant4 toolkit was used to study the system performance of the fusion reaction history diagnostic facility based on gas Cherenkov detector. The material and thickness of the radiation converter were optimized along with the pressure and length of the CO2 gas cavity. Simulation results indicate that the system time resolution and conversion efficiency reach about 22 ps and 4.710-3 Cherenkov photons/gamma respectively after optimization.