Xia Minghe, Ji Ce, Wang Yujuan, et al. Pulse output switch of Primary Test Stand[J]. High Power Laser and Particle Beams, 2012, 24: 2516-2520. doi: 10.3788/HPLPB20122410.2516
Citation:
Xia Minghe, Ji Ce, Wang Yujuan, et al. Pulse output switch of Primary Test Stand[J]. High Power Laser and Particle Beams, 2012, 24: 2516-2520. doi: 10.3788/HPLPB20122410.2516
Xia Minghe, Ji Ce, Wang Yujuan, et al. Pulse output switch of Primary Test Stand[J]. High Power Laser and Particle Beams, 2012, 24: 2516-2520. doi: 10.3788/HPLPB20122410.2516
Citation:
Xia Minghe, Ji Ce, Wang Yujuan, et al. Pulse output switch of Primary Test Stand[J]. High Power Laser and Particle Beams, 2012, 24: 2516-2520. doi: 10.3788/HPLPB20122410.2516
The self-breakdown water switch with coaxial-triplate configuration is used for the pulse output switch of the pulse forming section in Primary Test Stand (PTS). The research contains two stages, the first is the 1.5 MV coaxial water switch experiment on FLASH-Ⅱand the second is the experiment of 4 MV coaxial-triplate multi-channel water switch on the prototype module of PTS. Results show that the output current is 500 kA with 100 ns rise time at 3.5 MV self-breakdown voltage, the total switch inductance is 65 nH, and the jitter of charging time is 1.3 ns.