Chen Nan, Dai Man, Gao Feng, et al. Energy spectrum measurement with circular array method[J]. High Power Laser and Particle Beams, 2013, 25: 2995-2998. doi: 10.3788/HPLPB20132511.2995
Citation:
Chen Nan, Dai Man, Gao Feng, et al. Energy spectrum measurement with circular array method[J]. High Power Laser and Particle Beams, 2013, 25: 2995-2998. doi: 10.3788/HPLPB20132511.2995
Chen Nan, Dai Man, Gao Feng, et al. Energy spectrum measurement with circular array method[J]. High Power Laser and Particle Beams, 2013, 25: 2995-2998. doi: 10.3788/HPLPB20132511.2995
Citation:
Chen Nan, Dai Man, Gao Feng, et al. Energy spectrum measurement with circular array method[J]. High Power Laser and Particle Beams, 2013, 25: 2995-2998. doi: 10.3788/HPLPB20132511.2995
Measurement of high-energy X-ray energy spectrum is difficult in high-energy flash X-ray radiograph. According to previous studies, controlling the influence of diffusion to a certain extent is very important to improve the precision of energy spectrum measurement. In this paper, circular array method (CAM) is introduced to measuring X-ray energy spectrum. An experiment setup is designed. Simulation from Monte-Carlo suggests that it is possible to control the influence of diffusion within 4%.