Volume 26 Issue 02
Jan.  2014
Turn off MathJax
Article Contents
Yu Xinhua, Gao Xi, Jiang Yannan, et al. Design and experiment of TE11-HE11 mode converter for high-power gyroklystron[J]. High Power Laser and Particle Beams, 2014, 26: 023003. doi: 10.3788/HPLPB201426.023003
Citation: Yu Xinhua, Gao Xi, Jiang Yannan, et al. Design and experiment of TE11-HE11 mode converter for high-power gyroklystron[J]. High Power Laser and Particle Beams, 2014, 26: 023003. doi: 10.3788/HPLPB201426.023003

Design and experiment of TE11-HE11 mode converter for high-power gyroklystron

doi: 10.3788/HPLPB201426.023003
  • Received Date: 2013-08-09
  • Rev Recd Date: 2013-11-12
  • Publish Date: 2014-02-15
  • A circular TE11-HE11 mode converter with slots in its inner wall is designed for a 30.5 GHz klystron using the mode matching method. Calculations show the mode converter has a conversion of higher than 98.8% inside a 2.6% bandwidth. Experiments indicate it works well. The mode matching method has advantages of minimum memory consumption, high accuracy and rapid analysis speed over the other methods.