A 100kV/2A threephase constantcurrent repetitiverate charging equipment was designed and constructed. A threephase LC converter is adopted as constantcurrent power source. Six Insulated Gate Bipolar Transistors(IGBTs) are connected in parallel to control the stop of charge. A Programmable Logical Controller(PLC) is the central element of the control unit. The equipment is used in the repetitiverate discharge features test of the switch. It works stably under the conditions of 2A charging current, 10Hz operating voltage, 100kV repetitiverate and 1μF capacitor.