zhang yue-long, fang ben-jie, chen fang, et al. Primary experimental investigation on 1 kW class verti-COIL[J]. High Power Laser and Particle Beams, 2006, 18.
Citation:
zhang yue-long, fang ben-jie, chen fang, et al. Primary experimental investigation on 1 kW class verti-COIL[J]. High Power Laser and Particle Beams, 2006, 18.
zhang yue-long, fang ben-jie, chen fang, et al. Primary experimental investigation on 1 kW class verti-COIL[J]. High Power Laser and Particle Beams, 2006, 18.
Citation:
zhang yue-long, fang ben-jie, chen fang, et al. Primary experimental investigation on 1 kW class verti-COIL[J]. High Power Laser and Particle Beams, 2006, 18.
A verti-COIL with/without primary buffer gases was demonstrated in our laboratory. This verti-COIL represents the trend of less primary gases than traditional COIL. In the initial experimental stage, an output power of 1.3 kW and a chemical efficiency of 16.9% were obtained for a chlorine flowrate of 82 mmol/s, and its main parameters were compared with that of He-COIL (an output power of 2.4 kW and a chemical efficiency of 24% were obtained for a chlorine flowrate of 110 mmol/s) and that of N2-COIL (an output power of 2.38 kW and a chemical efficiency of 22.7% were obtained for a chlorine flowrate of 115 mmol/s). Primary experimental investigation indicated that, if the verti-COIL would have further reduced pτres value in SOG, and shortened I2/O2 mixing length in subsonic section or inje