The analysis of the EMP coupling to buried cables is important in EMP protection. Based on the Agrawal model of transmission line and the 1-D FDTD method, this coupling problem is studied. A linear fitting method is proposed to avoid the complicated convolution between ground impedance and transmission line voltage/current. The basic theory and calculation result of the method are introduced. A simple approach is provided to analyze the transmission line model in time-domain considering ground impedance. Comparison of the time domain and frequency domain calculation results shows the proposed method is effective and can solve the coupling problem in non-uniform environment where the frequency domain method does not work.