Volume 19 Issue 06
Jun.  2007
Turn off MathJax
Article Contents
xin jia-qi, chang an-bi, li ming-jia, et al. Voltage distribution in tapered winding of Tesla-transformer during discharge process of PFL[J]. High Power Laser and Particle Beams, 2007, 19.
Citation: xin jia-qi, chang an-bi, li ming-jia, et al. Voltage distribution in tapered winding of Tesla-transformer during discharge process of PFL[J]. High Power Laser and Particle Beams, 2007, 19.

Voltage distribution in tapered winding of Tesla-transformer during discharge process of PFL

  • Publish Date: 2007-06-15
  • The operation principle of integral construction of Tesla transformer and PFL was investigated in Tesla-transformer-type accelerator. Experiment was carried out on Tesla transformer’s secondary winding to study the impulse voltage distribution while PFL was discharging. The regularities of turn-ground voltage distribution and interturn voltage distribution were summarized. Voltage distribution within PFL was calculated and it was compared with the experimental result. Structural winding of parallel coils in the head, parallel coils in the end and shading ring were used to improve voltage distribution and that was testified by experiment. The results indicate that taper winding doesn’t effect electric field within PFL, the turn-ground voltage appears linearly, the interturn voltage fluctu
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2342) PDF downloads(396) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return