tao xiao-kui, he zhi-wen, xing qing-zi, et al. Simulation research on the instantaneous response of HPM pulse compression by SES method[J]. High Power Laser and Particle Beams, 2005, 17.
Citation:
tao xiao-kui, he zhi-wen, xing qing-zi, et al. Simulation research on the instantaneous response of HPM pulse compression by SES method[J]. High Power Laser and Particle Beams, 2005, 17.
tao xiao-kui, he zhi-wen, xing qing-zi, et al. Simulation research on the instantaneous response of HPM pulse compression by SES method[J]. High Power Laser and Particle Beams, 2005, 17.
Citation:
tao xiao-kui, he zhi-wen, xing qing-zi, et al. Simulation research on the instantaneous response of HPM pulse compression by SES method[J]. High Power Laser and Particle Beams, 2005, 17.
The paper presents the instantaneous response of stored energy, reflected power in the input coupler and output power in the output coupler due to the interactions of the power source and the “switch” under generating high power microwave pulse compression by SES (stored energy switch) method. Meanwhile, the whole process has been simulated by MATLAB code. The program developed can simulate situations of different intrinsic quality factors, input coupling coefficients, output coupling coefficients, power sources and switch times of the “switch” and so on, and display images of the process. It is helpful for understanding the instantaneous response and further research on the technique of HPM pulse compression.