Volume 23 Issue 01
Sep.  2012
Turn off MathJax
Article Contents
tan zhiyuan, gan kongyin, li ming, et al. 1:43.4 fractionalturn ratio pulse transformer[J]. High Power Laser and Particle Beams, 2011, 23.
Citation: tan zhiyuan, gan kongyin, li ming, et al. 1:43.4 fractionalturn ratio pulse transformer[J]. High Power Laser and Particle Beams, 2011, 23.

1:43.4 fractionalturn ratio pulse transformer

  • Publish Date: 2010-12-27
  • The fractionalturn ratio pulse transformer was theoretically analyzed, including the relationship between rise time and the number of secondary winding turns, area of magnetic core cross section as well as voltagetime product. A 1:43.4 turn ratio pulse transformer was designed and built accordingly. The secondary leakage inductance is 157.3 μH and the stray capacitance is 412 pF. The rise time is 894 ns in low voltage test. High voltage test of the pulse transformer connected with a 420 Ω fictitious load has been performed in oil. An output pulse with a peak voltage of 42.7 kV and a rise time of 917 ns was generated.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (1645) PDF downloads(611) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return