Volume 22 Issue 12
Dec.  2010
Turn off MathJax
Article Contents
gao yi, ma jiming, zhang zhong, et al. Spot size measurement for pulsed X-ray source with lamination method[J]. High Power Laser and Particle Beams, 2010, 22.
Citation: gao yi, ma jiming, zhang zhong, et al. Spot size measurement for pulsed X-ray source with lamination method[J]. High Power Laser and Particle Beams, 2010, 22.

Spot size measurement for pulsed X-ray source with lamination method

  • Publish Date: 2010-12-07
  • The principle of pulsed X-ray spot size measurement with lamination method was presented. The spatial resolution and output response for uniformly distributed line source of the metal-film lamination were calculated numerically. The corresponding relation between the FWHM of the response curve and the spot size was obtained. And the calculation results indicate that the metal-film lamination is not suitable for measurement of spot size less than 2 mm. Rod-pinch diode(RPD) experiments were performed on the inductive voltage adder, and the axial extent of the RPD X-ray source was measured with lamination method. Under the hypothesis of uniformly distributed line source, the axial spot size of the X-ray source was obtained, about 5.2 mm, consistent with the measuring result of the pinhole cam
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (1983) PDF downloads(591) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return