Volume 23 Issue 07
Sep.  2012
Turn off MathJax
Article Contents
zang yongdong, mao ruishi, wu junxia, et al. Schottky beam diagnostic system at CSRe[J]. High Power Laser and Particle Beams, 2011, 23.
Citation: zang yongdong, mao ruishi, wu junxia, et al. Schottky beam diagnostic system at CSRe[J]. High Power Laser and Particle Beams, 2011, 23.

Schottky beam diagnostic system at CSRe

  • Publish Date: 2011-07-21
  • Schottky diagnostics are often used in circular accelerators and in storage rings. A brief introduction on the longitudinal Schottky signal basics and a report on the elements of Schottky diagnostic system at CSRe are presented. The system consists of a pair of Schottky electrodes, λ/4 helical resonator, low noise amplifier and data acquisition device. Test measurement results of the frequency measurement and sensitivity measurement with 78Kr36+ beam of 481.88 MeV/u circulating in the storage ring CSRe are obtained. The results show that the system is sensitive to the beam current larger than 82 nA.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2244) PDF downloads(702) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return