sun ke-xu, jiang shao-en, yi rong-qing, et al. Response time measurement for a filter-X-ray diode detection system[J]. High Power Laser and Particle Beams, 2004, 16.
Citation: sun ke-xu, jiang shao-en, yi rong-qing, et al. Response time measurement for a filter-X-ray diode detection system[J]. High Power Laser and Particle Beams, 2004, 16.

Response time measurement for a filter-X-ray diode detection system

  • Publish Date: 2004-12-15
  • The detection system consists of filter,XRD,SUJ-50-10 cable and different band oscillograph. 20TW laser facility of Shanghai Laser Unite Laboratory with energy about 20J,pulse width about 1ps was used, and Au foil target irradiated by laser pulse produced X-ray emission. Note oscillograph type have TK684C,TK694C and WM8500. The linear fit and comparision analysis of experiment data are proceeded. The response time of a filterXRD detection system become fast along with based voltage, and become solw along with cable lenght. Therefor, when fast signal is measured, based voltage of detector must be inreased, and cable length be shorten, and high band oscillograph be selected, in order to reduce system response time and decrease signal distortion.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2304) PDF downloads(553) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return