Volume 16 Issue 03
Mar.  2004
Turn off MathJax
Article Contents
shang lei, wang xiang-qi, jiang dao-man, et al. Coating technology improvement of ceramic chamber and measurement of time characteristic of pulsed magnetic field[J]. High Power Laser and Particle Beams, 2004, 16.
Citation: shang lei, wang xiang-qi, jiang dao-man, et al. Coating technology improvement of ceramic chamber and measurement of time characteristic of pulsed magnetic field[J]. High Power Laser and Particle Beams, 2004, 16.

Coating technology improvement of ceramic chamber and measurement of time characteristic of pulsed magnetic field

  • Publish Date: 2004-03-15
  • Improvement status of HLS ceramic chambers was presented. A new method of inner surface coating of ceramic chambers with Mo-metallization was developed. The rise time characteristic of the pulsed magnetic field was greatly improved. Injection rate of the storage ring increased after installation of the new chamber. A two-coil method of measuring magnetic field was established. The resolution of rise time reaches nano-second range and the waveforms of measurement were presented.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2342) PDF downloads(544) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return