wang jue, zhang shi chang, yan ping, et al. Selfintegrating Rogowski coil for nanosecond current measurement[J]. High Power Laser and Particle Beams, 2004, 16.
Citation:
wang jue, zhang shi chang, yan ping, et al. Selfintegrating Rogowski coil for nanosecond current measurement[J]. High Power Laser and Particle Beams, 2004, 16.
wang jue, zhang shi chang, yan ping, et al. Selfintegrating Rogowski coil for nanosecond current measurement[J]. High Power Laser and Particle Beams, 2004, 16.
Citation:
wang jue, zhang shi chang, yan ping, et al. Selfintegrating Rogowski coil for nanosecond current measurement[J]. High Power Laser and Particle Beams, 2004, 16.
This paper introduces the advantage, purpose, principle and design of selfintegral Rogowski coil for nslevel current measurement. The response and distribute of Rogowski coil are discussed. The coil with a shield is treated as a distributed circuit, so that the toroidally wound coil acts as a delay line. The coil is calibrated. This coil could get the signal with rise time less than 2ns, value 10A~40kA, sensitivities about 1.4mV/A, pulsed width less than 200ns. The coil can be used in pulsed power technology for nslevel high current measurement.