liu zhi-min, xie jun, liu sheng, et al. Measurement of neutral beam power and beam profile distribution on DNB[J]. High Power Laser and Particle Beams, 2005, 17.
Citation:
liu zhi-min, xie jun, liu sheng, et al. Measurement of neutral beam power and beam profile distribution on DNB[J]. High Power Laser and Particle Beams, 2005, 17.
liu zhi-min, xie jun, liu sheng, et al. Measurement of neutral beam power and beam profile distribution on DNB[J]. High Power Laser and Particle Beams, 2005, 17.
Citation:
liu zhi-min, xie jun, liu sheng, et al. Measurement of neutral beam power and beam profile distribution on DNB[J]. High Power Laser and Particle Beams, 2005, 17.
The injection power of a diagnostic neutral beam (DNB) can be obtained with the thermocouple probe measurement system on the Hefei superconducting Tokamak-7 (HT-7). With the 49 kV, 6 A, 100 ms pulse charge of an acceleration electrode, a thermocouple probe measurement system with 13 thermocouples crossly distributed on a coppery heat target was used to measure the temperature rise of the target, and the maximum measured temperature rise was 14 ℃. And the neutral beam power of 160 kW and beam profile distribution were obtained by calculation. The total neutral beam power of 130 kW was also obtained by integral calculation with the temperature rise on the heat section board. The difference between the two means was analyzed. The experiment result shows that the method of heat section board