Volume 15 Issue 11
Nov.  2003
Turn off MathJax
Article Contents
zhang bing, li jia yin, yang zi qiang, et al. Crowbartube switch method to remove prepulsevoltage[J]. High Power Laser and Particle Beams, 2003, 15.
Citation: zhang bing, li jia yin, yang zi qiang, et al. Crowbartube switch method to remove prepulsevoltage[J]. High Power Laser and Particle Beams, 2003, 15.

Crowbartube switch method to remove prepulsevoltage

  • Publish Date: 2003-11-15
  • The prepulse phenomena in the discharge process of accelerator are analyzed in this paper. The prepulse will result in forming plasma, and further affect the diode performance. To remove or reduce this effect, a crowbar tube with cold cathode was adopted in the accelerator. The results show that prepulse voltage decreased from about 150kV to 50kV after adopting crowbar tube. The output power of relativistic backwardwave oscillator increased from 50MW to 250MW under the same condition. The frequency of relativistic magnetron tended to be reasonable obviously too.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views (2167) PDF downloads(544) Cited by()